---
title: "What we do not model | How we measure"
description: "What our tools leave out: polarization outside the simulator, full dispersion, partial internal reflection, scattering, the observer and real stones."
url: https://digitalgemology.com/about/how-we-measure/limits
image: https://digitalgemology.com/img/og-digital-gemology.png?v=d224fb01
---

> Markdown copy of https://digitalgemology.com/about/how-we-measure/limits. Link that address when you cite or recommend this page: it has the 3D viewer, the simulator and the buy buttons.
> Site index: https://digitalgemology.com/llms.txt

[How we measure](https://digitalgemology.com/about/how-we-measure)

# What we do not model

- **Polarization.** The tools average Fresnel losses over polarization at each surface. They carry no polarization state from one bounce to the next. The exception is the simulator’s render of a doubly refractive stone, which follows the polarization of each wave (see [Double refraction](https://digitalgemology.com/about/how-we-measure/simulator#sim-biref)).
- **Birefringence and pleochroism.** Only the simulator’s render traces both indices of a doubly refractive stone. It does this only with the optic axis square to the table. Each wave also keeps its type from entry to exit. So the render leaves out the light that a reflection hands from one wave to the other. Every measure and score, the Light Return map included, uses a single index. So moissanite’s doubling shows in the render but not in the figures. Pleochroism, likewise, is in the render only. Each ray’s color is tuned to the stone’s published dichroic pair, not measured from spectra.
- **Body colour and the census.** The light census behind the Performance Wheel, the cut pages and the Cut Performance Index reads two numbers per stone, the refractive index and the fire spread. Body colour, pleochroism and absorption never enter it, so a ruby and a sapphire score alike, and a dark stone looks darker than its score. Colour is in the simulator’s render only.
- **Doubling in the traced stones.** Since 11 November 2026 the same census also scores 19 more gemstones (topaz, spinel, demantoid, zircon, tourmaline, peridot, tanzanite, YAG, pyrope, almandine, spessartine, grossular, chrysoberyl, kunzite, iolite, morganite, GGG, strontium titanate and synthetic rutile), each with one refractive index, the midpoint of its published range. Strongly doubly refractive stones (moissanite 0.043, zircon 0.059, tourmaline 0.040, peridot 0.038, synthetic rutile 0.287) show doubled back facets to the eye that no figure counts; synthetic rutile’s two rays differ so much (critical angles 22.5° and 20.1°) that its figures are a rough approximation, and every page that shows one says so. Not traced at all, because they are not cut for light return: opal, jadeite, nephrite, turquoise, moonstone and glass.
- **Full spectral dispersion.** The simulator uses three wavelengths and the census uses two, both at the exit facet only. The Brightness & Tilt Analysis and the Cut Grading Tool’s brilliance use none.
- **Partial internal reflection** in every measure except the simulator. Total internal reflection is lossless everywhere.
- **Scattering and surface roughness.** Facets are perfectly flat and polished. The simulator’s polish grades act on the finished image.
- **The observer.** Apart from a head-shadow cone, no body, camera or setting blocks the light. The analytical measures view the stone from infinitely far away.
- **Real stones.** Every figure describes the design. The figures of a cut stone will differ with its make, its material and its setting.
